General Specifications:
Digital Display: 3-3/4 digits with maximum reading of 3999
Analog Display: Fast 42-segment analog bar graph display
Overload: Displays OL when input signal exceeds measuring limit in 40 A, 400 A, resistance, and continuity functions.
Sample Rate: 2 times/sec for digital display; 20 times/sec for analog bar graph
Low Battery Indication: Displays B when the battery is below its required voltage
Power Source: 9 V battery, NEDA1604 or 6F22 or 006P
Auto Power Off: The Meter will power itself off if there is no push button or rotary function switch operation for 30 minutes. Turn the rotary switch to “OFF” before turning the Meter on again.
To deactivate this feature, press the Peak button and keep it pressed down while powering up the Meter.
Clamp Opening Size:
312: 36 mm (1.42 inches)
Dimensions (L x W x H): 254 x 66 x 37 mm (10 x 2.60 x 1.45 inches)
Weight: 422 g (14.9 ounces) (battery included)
Included Accessories: Users manual, carrying case, test leads, 9 V battery
Approvals: P, EN61010 600 V CAT III, 1000 V CAT II, CMC
Continuity: On at < 50ohms
Diode Test: Up to 2V
Min Max: 500ms acquisition time
Input Impedance: 10MΩ
Auto Shut-off: After 30min±2min. Disabled in Min Max. Can be disabled as a power up option (hold down the peak button)
Auto range: Available in the following measurement functions: Volts & Ohms
Overload Protection: 600 Vrms per EN61010 CAT III 600V