BSDIE Smart AC Digital Clamp Meter With NCV
Features:
The instrument shall be re-calibrated at an interval of one year under the conditions of 18 �-28 �
and relative humidity of less than 75%.
Specifications:
The instrument is designed to automatically select measurement functions and measuring ranges.
Full range overload protection.
Allowable max voltage between terminal to be measured and ground:600V DC or 600V AC
Working weight: Max. 2000m
Display unit: LCD
Max display value: 6000 numbers
Polarity indication: automatic indication.‘-’indicates negative polarity.
Over range indication:‘0L’ or ‘-0L’
Sampling rate: approximately 3 times per second
Unit display: to display functions and electric quantity
Automatic shut-down time:10 minutes
Power supply: 1.5V AAA battery ×2
Battery under-voltage indication: LCD display symbol
Temperature coefficient: less than0.1x accuracy/�
Working temperature:18� ~ 28�
Storage temperature:-10� ~ 50�
PRODUCT DETAILS
Current clamp
Clamp diameter ize 20mm for
AC current measurements,
Hold a trigger, open clamp
head, and catch one guide
wire of a line to be measured
Data hold Backlight key
Reading hold
During the process of measurement,
gently touch the Data hold/Backlight
ke monitor's display value will be
locked. Touch again the Data hold/
Backlight ke the readings hold will
be removed
Data hold Backlight key
Backlight
In the process of measurement, if the
measurement environment is too
dark, press the key Data hold/
Backlight for more than 2 seconds to
enable backlight function. Then
about 1 minute later, the backlight
function will be automatically disabled.
Func key
select measurement functions
Press the HZ key to switch to
DC voltage measurement
mode/ Press Hz/NVC key for 2
seconds to enable NCV function
Display screen
6000 digital LCD displays clear,
backlit read data more convenient
MEASUREMENT OPERATION
Measurement of AC current and AC current frequency
1.Hold a trigger, open clamp head,
and catch one guide wire of a line to
be measured
2. When the measured current of the
signal is 0.01A, the instrument's
primary display panel will display the
measured current value. Press HZ key
to display the frequency value of the
measured current
DC voltage measurement
When the pen-shaped meter is connected
to the signal to be measured and the
measured AC signal>=1.0V, the instrument
will display the measured AC voltage.
When HZ key is pressed, it will switch to
the frequency value of the voltage. When
the measured AC signal <1.0V, the
instrument will accept the resistance as
the default resistance and display the
internal resistance of the measured signal.
Electric resistance measurement
Connect the pen-shaped meter with
the resistance being measured. When
the measured resistance is >6k, �the
instrument will display- - - -; when
the measured resistance is less than
50�, the buzzer will sound alarms
and On/Off indicator will be on
simultaneously
Non contact voltage Non contact voltage
1.Press Hz/NVC key for 2 seconds to
enable NCV function. Then the
instrument will display
2. Press NCV key and move NCV
sensor closer to the lead line to be
measured. The instrument can detect
whether the AC voltage of the
measured lead line is >90V. When
the instrument detects AC voltage,
the buzzer will sound alarms while
backlight flickers.